ML601
Relay
8A,10A PCB 20.1*15*10.2
Product Overview

High contact switching capability

Withstand voltage between coil and contact is 4KV

Available in monostable and bistable form

Contact form:1A,1B,2A,2B,1AB

Environmental friendly products (RoHS compliant)

Product Features
  • Complete Product Specifications
  • Long Lifespan Stable Performance
  • Small Size High Current
  • Nergy Conservation & Environmental Protection
SELLING POINT OF PRODUCTS

Advantage 1:External wiring and contacts: pure copper  silver alloy contacts, good performance, fast switching

Advantage 2:External structure and material: the shell is made of flame-retardant material, four-sided buckle design, reliable structure

Advantage 3:The internal structure and material use silver alloy contact, permanent magnet, pure copper coil, longer life and safer

Advantage 4 Complete specifications: to meet the use of different types of electricity and smart meter products


Product Parameters

Contact Parameters

Contact Form

1A、1B (Bistable type)

2A、2B、1AB

Contact Material

Silver Alloy

Contact Resistance

<=50mΩ(1A 6VDC)

Contact Rating

10A 250VAC

8A 250VAC

Max. Switching Current

10A        8A

Max. Switching Voltage

250VAC

Max. Switching Power

2500KV    2000KV

Electrical Life

100000 OPS

Mechanical Life

1000000 OPS


Characteristics

Insulation Resistance

1000MΩ Min (500VDC)

Dielectric Strength

Between Coil&Contacts:4000VAC 1min

Between Open Contacts:1000VAC 1MIN

Set Time

<=10ms

Reset Time

<=10ms

Shock

Functional:98m/s²

Destructive:980m/s²

Vibration

10Hz~55Hz 1.5mm(DA)

Humidity

5%~85%RH

Ambient Temperature

-40℃~+85℃

Termination

PCB

Construction

Sealed

Flux Proofed

Unit Weight

Approx.6g

Use The Information

The ML601 relay is suitable for various electrical control scenarios, such as Security control, temperature control, curtain control, smart socket and smart panel, lighting control, central control template. When using the ML601 relay, first, choose the appropriate model according to actual needs to ensure that its electrical parameters match the circuit requirements. Then, when installing the relay, choose a suitable location, away from high temperatures, moisture, and corrosive environments, and maintain good ventilation conditions. During wiring, strictly follow the wiring diagram to ensure correct wiring and reliable contact. Pay attention to maintaining a suitable working environment temperature during operation, regularly inspect and maintain the relay, and prevent safety issues. If any abnormalities occur, stop using it promptly and conduct inspection and repairs to ensure the safe and stable operation of the relay and circuit.

Exchanged Notes
  • The quality problem

    We offer a one-year product warranty. If any issues arise within this period due to product defects, we will provide free replacements or refunds.

PRODUCTION PROCESS

image.jpeg

CERTIFICATE

image.png

PRODUCT PACKAGING

We can customize the packaging according to your needs.

ORDER PRODUCTION PROCESS

image.jpeg

PRODUCTION EQUIPMENT

未标题-1.png

Related Products